Product type
Control units and power transmitters
Execution
The device complies with the following regulations:
• 2014/35/EU – Low Voltage Directive
• 2014/30/EU – Directive on electromagnetic compatibility
• RL 2011/65/EU – RoHS
A safety contact in the control unit can be used to prevent machining of
the workpiece when the clamping device is not switched on. Illuminated
pushbuttons are used for manual control. Optional connection to a CNC
control system is via a 24-volt signal voltage. A stepped holding force
adjustment is installed as standard. This can be adjusted via a coding
switch. When using the lower holding force adjustment levels, please note
that safety according to accident prevention regulations is no longer
guaranteed. However, the release level can be adjusted to suit the
workpiece. Maximum ambient temperature: 45°C. Power supply: 230/400 V DC.
Frequency: 50/60 Hz. Duty cycle for electromagnets: 100%.